MIL-DTL 28875/5A
TABLE II. Dimension, physical and environmental characteristics.
Dimension
Dash
Temperature range
Mass
Burn-in
A in
Seal
Salt
temperature
number
Max
inches
(Grams)
(case temp)
(mm)
Operating
Nonoperating
Max
case temp
S1
-54/+85°C
-65/+100°C
+100°C
01
S2
.22 (5,6)
2.5
Hermetic
Applicable
N
S1
-55/+100°C
-65/+125°C
+100°C
02
S2
.27 (6.8)
2.5
Hermetic
Applicable
N
S1
-54/+85°C
-65/+100°C
+125°C
03
S2
.18 (4.6)
2.5
Hermetic
Applicable
N
S1
-54/+85°C
-65/+100°C
+100°C
04
S2
.18 (4.6)
2.5
Hermetic
Applicable
N
S1
-54/+85°C
-65/+100°C
+125°C
05
S2
.18 (4.6)
2.5
Hermetic
Applicable
N
S1
-54/+85°C
-65/+100°C
+125°C
06
S2
.18 (4.6)
2.5
Hermetic
Applicable
N
S1
-54/+85°C
-65/+100°C
+125°C
07
S2
.18 (4.6)
2.5
Hermetic
Applicable
N
S1
-54/+85°C
-65/+100°C
+125°C
08
S2
.18 (4.6)
2.5
Hermetic
Applicable
N
S1
-54/+85°C
-65/+100°C
+125°C
09
S2
.18 (4.6)
2.5
Hermetic
Applicable
N
S1
-54/+85°C
-65/+100°C
+100°C
10
S2
.22 (5.6)
2.5
Hermetic
Applicable
N
S1
-54/+100°C
-62/+125°C
+125°C
11
S2
.22 (5.6)
2.5
Hermetic
Applicable
N
S1
-54/+100°C
-62/+125°C
+125°C
12
S2
.22 (5.6)
2.5
Hermetic
Applicable
N
4